Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/12908
DC FieldValueLanguage
dc.contributor.authorBento, A. C. S. S. M.-
dc.contributor.authorSantos, J. M. F. dos-
dc.contributor.authorMorgado, R. E.-
dc.date.accessioned2010-03-15T15:24:38Z-
dc.date.available2010-03-15T15:24:38Z-
dc.date.issued1997-06-
dc.identifier.citationIEEE Transactions on Nuclear Science. 44:3 (1997) 527-533en_US
dc.identifier.issn0018-9499-
dc.identifier.urihttps://hdl.handle.net/10316/12908-
dc.description.abstractIn the present work we revisit the simplifying assumptions of an earlier theoretical treatment on the effects of grid misalignment on the performance of a planar gas proportional scintillation counter (GPSC). We present new experimental and computational results to establish the dependence of the effects of misalignment in terms of the reduced electric field in the scintillation region, the finite size of the electron cloud, and the solid angle subtended by the photosensor. It is shown that solid angle effects will offset to some degree the effects of grid misalignment in an optimized detector. For the reduced fields normally used in the scintillation region of an optimized GPSC (5 V cm -1 torr-1), misalignments as large as 3% have less than a 2% effect on pulse-amplitude variations. This effect is less than the statistical fluctuations in the number of primary electrons nominally produced in the absorption of X-rays in the 1- to 6-keV energy region. For reduced fields closer to the scintillation threshold (1 Vcm -1 torr-1), 15% variations in pulse amplitudes are possible, although it is unlikely that a GPSC would be operated under such unfavorable conditionsen_US
dc.language.isoengen_US
dc.publisherIEEEen_US
dc.rightsopenAccessen_US
dc.titleThe effect of grid misalignment on the uniformity of response of gas proportional scintillation countersen_US
dc.typearticleen_US
dc.identifier.doi10.1109/23.603705-
item.fulltextCom Texto completo-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.grantfulltextopen-
item.cerifentitytypePublications-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-8841-6523-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
The effect of grid misalignment.pdf745.97 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

2
checked on Jul 22, 2024

WEB OF SCIENCETM
Citations

2
checked on Jul 2, 2024

Page view(s) 50

504
checked on Jul 23, 2024

Download(s)

370
checked on Jul 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.