Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/12892
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Carmo, S. J. C. do | - |
dc.contributor.author | Borges, F. I. G. M. | - |
dc.contributor.author | Conde, C. A. N. | - |
dc.date.accessioned | 2010-03-15T10:02:27Z | - |
dc.date.available | 2010-03-15T10:02:27Z | - |
dc.date.issued | 2009-04 | - |
dc.identifier.citation | IEEE Transactions on Nuclear Science 56:2 (2009) 437-440 | en_US |
dc.identifier.issn | 0018-9499 | - |
dc.identifier.uri | https://hdl.handle.net/10316/12892 | - |
dc.description.abstract | The performance of a gas proportional scintillation counter filled with either pure Xe or Ar-Xe mixtures is described for the 0.1-10 keV X-ray energy range. It is shown that the spectra tail distortion exhibited by Xe filled gaseous detectors for soft X-rays below 2 keV is reduced if Ar-Xe mixtures are used. The peak-to-valley ratio increases by a factor of about 2 or 3 as the Xe concentration is reduced from 100% to 5%. Moreover, the energy resolutions for such mixtures are similar to the ones for pure Xe | en_US |
dc.language.iso | eng | en_US |
dc.publisher | IEEE | en_US |
dc.rights | openAccess | en_US |
dc.subject | Argon detectors | en_US |
dc.subject | Energy resolution | en_US |
dc.subject | Gas detectors | en_US |
dc.subject | Proportional gas scintillation detectors | en_US |
dc.subject | X-ray detectors | en_US |
dc.subject | X-ray spectroscopy | en_US |
dc.subject | Xenon detectors | en_US |
dc.title | Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1109/NSSMIC.2008.4774540 | - |
item.fulltext | Com Texto completo | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
crisitem.author.researchunit | LIP – Laboratory of Instrumentation and Experimental Particle Physics | - |
crisitem.author.orcid | 0000-0003-4631-7268 | - |
Appears in Collections: | FCTUC Física - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Performance of Argon-Xenon Mixtures.pdf | 321.43 kB | Adobe PDF | View/Open |
Page view(s)
310
checked on Oct 15, 2024
Download(s)
370
checked on Oct 15, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.