Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/114546
DC FieldValueLanguage
dc.contributor.authorLoureiro, João-
dc.contributor.authorBogatu, Laura-
dc.contributor.authorSchmitt, Lars-
dc.contributor.authorHenriques, Jorge-
dc.contributor.authorCarvalho, Paulo-
dc.contributor.authorNoordergraaf, Gerrit J.-
dc.contributor.authorPaulussen, Igor-
dc.contributor.authorMuehlsteff, Jens-
dc.date.accessioned2024-04-01T08:45:07Z-
dc.date.available2024-04-01T08:45:07Z-
dc.date.issued2023-
dc.identifier.issn1664-042Xpt
dc.identifier.urihttps://hdl.handle.net/10316/114546-
dc.description.abstractBlood pressure (BP) surrogates, such as pulse transit time (PTT) or pulse arrival time (PAT), have been intensively explored with the goal of achieving cuffless, continuous, and accurate BP inference. In order to estimate BP, a one-point calibration strategy between PAT and BP is typically used. Recent research focuses on advanced calibration procedures exploiting the cuff inflation process to improve calibration robustness by active and controlled modulation of peripheral PAT, as measured via plethysmograph (PPG) and electrocardiogram (ECG) combination. Such methods require a detailed understanding of the mechanisms behind the vasculature's response to cuff inflation; for this, a model has recently been developed to infer the PAT-BP calibration from measured cuff-induced vasculature changes. The model, while promising, is still preliminary and only partially validated; in-depth analysis and further developments are still needed. Therefore, this work aims to improve our understanding of the cuff-vasculature interaction in this model; we seek to define potential opportunities and to highlight which aspects may require further study. We compare model behaviors with clinical data samples based on a set of observable characteristics relevant for BP inference and calibration. It is found that the observed behaviors are qualitatively well represented with the current simulation model and complexity, with limitations regarding the prediction of the onset of the distal arm dynamics and behavior changes at high cuff pressures. Additionally, a sensitivity analysis of the model's parameter space is conducted to show the factors that influence the characteristics of its observable outputs. It was revealed that easily controllable experimental variables, such as lateral cuff length and inflation rate, have a significant impact on cuff-induced vasculature changes. An interesting dependency between systemic BP and cuff-induced distal PTT change is also found, revealing opportunities for improved methods for BP surrogate calibration. However, validation via patient data shows that this relation does not hold for all patients, indicating required model improvements to be validated in follow up studies. These results provide promising directions to improve the calibration process featuring cuff inflation towards accurate and robust non-invasive blood pressure estimation.pt
dc.language.isoengpt
dc.publisherFrontiers Media S.A.pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt
dc.subjectblood pressurept
dc.subjectpulse arrival timept
dc.subjectoscillometrypt
dc.subjectblood pressure surrogate calibrationpt
dc.subjecthemodynamic modelpt
dc.subjectpulse transit timept
dc.subjectNIBPpt
dc.titleTowards continuous non-invasive blood pressure measurements-interpretation of the vasculature response to cuff inflationpt
dc.typearticle-
degois.publication.firstPage1172688pt
degois.publication.titleFrontiers in Physiologypt
dc.peerreviewedyespt
dc.identifier.doi10.3389/fphys.2023.1172688pt
degois.publication.volume14pt
dc.date.embargo2023-01-01*
uc.date.periodoEmbargo0pt
item.cerifentitytypePublications-
item.languageiso639-1en-
item.fulltextCom Texto completo-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
crisitem.author.researchunitCISUC - Centre for Informatics and Systems of the University of Coimbra-
crisitem.author.researchunitCISUC - Centre for Informatics and Systems of the University of Coimbra-
crisitem.author.parentresearchunitFaculty of Sciences and Technology-
crisitem.author.parentresearchunitFaculty of Sciences and Technology-
crisitem.author.orcid0000-0003-4622-474X-
crisitem.author.orcid0000-0002-9847-0590-
Appears in Collections:FCTUC Eng.Informática - Artigos em Revistas Internacionais
I&D CISUC - Artigos em Revistas Internacionais
Show simple item record

Page view(s)

19
checked on May 15, 2024

Download(s)

10
checked on May 15, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons