Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/109153
DC FieldValueLanguage
dc.contributor.authorSeehaus, Arne-
dc.contributor.authorRoebroeck, Alard-
dc.contributor.authorBastiani, Matteo-
dc.contributor.authorFonseca, Lúcia-
dc.contributor.authorBratzke, Hansjürgen-
dc.contributor.authorLori, Nicolás-
dc.contributor.authorVilanova, Anna-
dc.contributor.authorGoebel, Rainer-
dc.contributor.authorGaluske, Ralf-
dc.date.accessioned2023-09-29T08:45:20Z-
dc.date.available2023-09-29T08:45:20Z-
dc.date.issued2015-
dc.identifier.issn1662-5129pt
dc.identifier.urihttps://hdl.handle.net/10316/109153-
dc.description.abstractDiffusion tensor imaging (DTI) is amongst the simplest mathematical models available for diffusion magnetic resonance imaging, yet still by far the most used one. Despite the success of DTI as an imaging tool for white matter fibers, its anatomical underpinnings on a microstructural basis remain unclear. In this study, we used 65 myelin-stained sections of human premotor cortex to validate modeled fiber orientations and oft used microstructure-sensitive scalar measures of DTI on the level of individual voxels. We performed this validation on high spatial resolution diffusion MRI acquisitions investigating both white and gray matter. We found a very good agreement between DTI and myelin orientations with the majority of voxels showing angular differences less than 10°. The agreement was strongest in white matter, particularly in unidirectional fiber pathways. In gray matter, the agreement was good in the deeper layers highlighting radial fiber directions even at lower fractional anisotropy (FA) compared to white matter. This result has potentially important implications for tractography algorithms applied to high resolution diffusion MRI data if the aim is to move across the gray/white matter boundary. We found strong relationships between myelin microstructure and DTI-based microstructure-sensitive measures. High FA values were linked to high myelin density and a sharply tuned histological orientation profile. Conversely, high values of mean diffusivity (MD) were linked to bimodal or diffuse orientation distributions and low myelin density. At high spatial resolution, DTI-based measures can be highly sensitive to white and gray matter microstructure despite being relatively unspecific to concrete microarchitectural aspects.pt
dc.language.isoengpt
dc.publisherFrontiers Media S.A.pt
dc.relationEuropean Research Council (ERC-2010-AdG)pt
dc.relationFCT Ciência2007pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt
dc.subjectdiffusion microstructurept
dc.subjectdiffusion tensor imagingpt
dc.subjectfiber orientationspt
dc.subjectgray matterpt
dc.subjecthistological validationpt
dc.titleHistological validation of high-resolution DTI in human post mortem tissuept
dc.typearticle-
degois.publication.firstPage98pt
degois.publication.titleFrontiers in Neuroanatomypt
dc.peerreviewedyespt
dc.identifier.doi10.3389/fnana.2015.00098pt
degois.publication.volume9pt
dc.date.embargo2015-01-01*
uc.date.periodoEmbargo0pt
item.grantfulltextopen-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairetypearticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextCom Texto completo-
crisitem.author.orcid0000-0002-5895-0880-
Appears in Collections:I&D IBILI - Artigos em Revistas Internacionais
Files in This Item:
Show simple item record

Page view(s)

26
checked on May 8, 2024

Download(s)

20
checked on May 8, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons