Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/109097
Title: Desenvolvimento e validação de método para quantificação simultânea de ofloxacina, norfloxacina e ciprofloxacina em urina humana
Other Titles: Development and validation of an analytical method for the simultaneous quantification of ofloxacin, norfloxacin and ciprofloxacin in human urine
Authors: Zanchetta, Priscilla Garozi
Pena, Angelina 
Gonçalves, Ricardo Franci
Keywords: fluoroquinolonas; validação; CLAE-DF; fluoroquinolones; validation; HPLC-FD
Issue Date: 2015
Publisher: Associacao Brasileira de Engenharia Sanitaria e Ambiental
Serial title, monograph or event: Engenharia Sanitaria e Ambiental
Volume: 20
Issue: 2
Abstract: Processos de tratamentos têm sido alvo de estudos com a finalidade de promover a remoção dos fármacos na urina humana de forma a garantir a segurança ambiental da utilização dessa como fertilizante na agricultura. Neste artigo foi desenvolvido e validado um método de CLAE-DF para a determinação simultânea de ofloxacina, norfloxacina e ciprofloxacina na urina humana. O método proposto descreve uma alternativa eficaz para a determinação de resíduos de fluoroquinolonas, eliminando o passo de limpeza. Além disso, o método proposto demonstrou ser seletivo, com boa linearidade (r>0,99), sensibilidade, precisão (80% a 107%) e repetitividade. Este método mostra ser adequado para análises de rotina (de baixo custo, simples, e utilizando pequeno volume de solventes) para abordagens ecológicas.
Treatment processes have been the focus of studies aiming at promoting the removal of drugs in human urine in order to ensure environmental safety using it as a fertilizer in agriculture. So, an HPLC-FD method for the simultaneous determination of ofloxacin, norfloxacin and ciprofloxacin in human urine was developed and validated. The proposed method describes an efficient alternative for the determination of fluoroquinolone residues by eliminating the clean-up step. Moreover, the proposed method proved to be selective, with good linearity (r>0.99), sensitivity, accuracy (80% to 107%) and repeatability. This method shows to be suitable for routine analyses (simple, low price and using a small volume of solvents) for ecological approaches.
URI: https://hdl.handle.net/10316/109097
ISSN: 1413-4152
DOI: 10.1590/S1413-41522015020000114433
Rights: openAccess
Appears in Collections:FFUC- Artigos em Revistas Internacionais

Show full item record

Page view(s)

33
checked on Apr 24, 2024

Download(s)

9
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons