Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/106708
DC FieldValueLanguage
dc.contributor.authorSeidel, Philipp-
dc.contributor.authorLevine, Seth M.-
dc.contributor.authorTahedl, Marlene-
dc.contributor.authorSchwarzbach, Jens V.-
dc.date.accessioned2023-04-18T08:53:32Z-
dc.date.available2023-04-18T08:53:32Z-
dc.date.issued2020-03-26-
dc.identifier.issn2045-2322pt
dc.identifier.urihttps://hdl.handle.net/10316/106708-
dc.description.abstractEcho-planar imaging (EPI) is the most common method of functional MRI for acquiring the blood oxygenation level-dependent (BOLD) contrast, allowing the acquisition of an entire brain volume within seconds. However, because imaging protocols are limited by hardware (e.g., fast gradient switching), researchers must compromise between spatial resolution, temporal resolution, or whole-brain coverage. Earlier attempts to circumvent this problem included developing protocols in which slices of a volume were acquired faster (i.e., in-plane acceleration (S)) or simultaneously (i.e., multislice acceleration (M)). However, applying acceleration methods can lead to a reduction in the temporal signal-to-noise ratio (tSNR): a critical measure of signal stability over time. Using a 20- and 64-channel receiver coil, we show that enabling S-acceleration consistently yielded a substantial decrease in tSNR, regardless of the receiver coil, whereas M-acceleration yielded less pronounced tSNR decrease. Moreover, tSNR losses tended to occur in temporal, insular, and medial brain regions and were more noticeable with the 20-channel coil, while with the 64-channel coil, the tSNR in lateral frontoparietal regions remained relatively stable up to six-fold M-acceleration producing comparable tSNR to that of no acceleration. Such methodological explorations can guide researchers and clinicians in optimizing imaging protocols depending on the brain regions under investigation.pt
dc.language.isoengpt
dc.publisherSpringer Naturept
dc.relationM.T. was supported by a scholarship from the Universität Bayern e.V.pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt
dc.titleTemporal Signal-to-Noise Changes in Combined Multislice- and In-Plane-Accelerated Echo-Planar Imaging with a 20- and 64-Channel Coilpt
dc.typearticle-
degois.publication.firstPage5536pt
degois.publication.issue1pt
degois.publication.titleScientific Reportspt
dc.peerreviewedyespt
dc.identifier.doi10.1038/s41598-020-62590-ypt
degois.publication.volume10pt
dc.date.embargo2020-03-26*
uc.date.periodoEmbargo0pt
item.openairetypearticle-
item.fulltextCom Texto completo-
item.languageiso639-1en-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.researchunitCenter for Research in Neuropsychology and Cognitive Behavioral Intervention (CINEICC)-
crisitem.author.parentresearchunitFaculty of Psychology and Educational Sciences-
Appears in Collections:FPCEUC - Artigos em Revistas Internacionais
Show simple item record

SCOPUSTM   
Citations

10
checked on Jul 1, 2024

WEB OF SCIENCETM
Citations

9
checked on Jul 2, 2024

Page view(s)

20
checked on Jul 16, 2024

Download(s)

27
checked on Jul 16, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons