Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/105929
DC FieldValueLanguage
dc.contributor.authorSantos, Paulo-
dc.contributor.authorLemes, Gabriela-
dc.contributor.authorMateus, Diogo-
dc.date.accessioned2023-03-15T10:25:42Z-
dc.date.available2023-03-15T10:25:42Z-
dc.date.issued2020-
dc.identifier.issn1996-1073-
dc.identifier.urihttps://hdl.handle.net/10316/105929-
dc.description.abstractAn accurate evaluation of the thermal transmittance (U-value) of building envelope elements is fundamental for a reliable assessment of their thermal behaviour and energy e ciency. Simplified analytical methods to estimate the U-value of building elements could be very useful to designers. However, the analytical methods applied to lightweight steel framed (LSF) elements have some specific features, being more challenging to use and to obtain a reliable accurate U-value with. In this work, the main analytical methods available in the literature were identified, the calculation procedures were reviewed and their accuracy was evaluated and compared. With this goal, six analytical methods were used to estimate the U-values of 80 di erent LSF wall models. The obtained analytical U-values were compared with those provided by numerical simulations, which were used as reference U-values. The numerical simulations were performed using a 2D steady-state finite element method (FEM)-based software, THERM. The reliability of these numerical models was ensured by comparison with benchmark values and by an experimental validation. All the evaluated analytical methods showed a quite good accuracy performance, the worst accuracy being found in cold frame walls. The best and worst precisions were found in the Modified Zone Method and in the Gorgolewski Method 2, respectively. Very surprisingly, the ISO 6946 Combined Method showed a better average precision than other two methods, which were specifically developed for LSF elements.pt
dc.language.isoengpt
dc.publisherMDPIpt
dc.relationPOCI-01-0145-FEDER-032061pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt
dc.subjectlightweight steel framept
dc.subjectLSF wallspt
dc.subjectthermal transmittancept
dc.subjectU-valuept
dc.subjectanalytical methodspt
dc.subjectcalculation procedurespt
dc.subjectaccuracypt
dc.titleAnalytical Methods to Estimate the Thermal Transmittance of LSF Walls: Calculation Procedures Review and Accuracy Comparisonpt
dc.typearticlept
degois.publication.firstPage840pt
degois.publication.issue4pt
degois.publication.titleEnergiespt
dc.peerreviewedyespt
dc.identifier.doi10.3390/en13040840-
degois.publication.volume13pt
dc.date.embargo2020-01-01*
uc.date.periodoEmbargo0pt
item.grantfulltextopen-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairetypearticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextCom Texto completo-
crisitem.author.researchunitISISE - Institute for Sustainability and Innovation in Structural Engineering-
crisitem.author.researchunitISISE - Institute for Sustainability and Innovation in Structural Engineering-
crisitem.author.orcid0000-0002-0134-6762-
crisitem.author.orcid0000-0002-4130-4786-
Appears in Collections:I&D ISISE - Artigos em Revistas Internacionais
Show simple item record

SCOPUSTM   
Citations

20
checked on Apr 29, 2024

WEB OF SCIENCETM
Citations

18
checked on May 2, 2024

Page view(s)

59
checked on May 7, 2024

Download(s)

76
checked on May 7, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons