Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/10369
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Pauliukaite, Rasa | - |
dc.contributor.author | Ghica, Mariana Emilia | - |
dc.contributor.author | Fatibello-Filho, Orlando | - |
dc.contributor.author | Brett, Christopher M. A. | - |
dc.date.accessioned | 2009-06-25T16:53:33Z | - |
dc.date.available | 2009-06-25T16:53:33Z | - |
dc.date.issued | 2009-07-01 | - |
dc.identifier.citation | Analytical Chemistry. 81:13 (2009) 5364-5372 | en_US |
dc.identifier.issn | 0003-2700 | - |
dc.identifier.uri | https://hdl.handle.net/10316/10369 | - |
dc.description.abstract | The effectiveness of immobilization of functionalized carbon nanotubes into chitosan using different cross-linking agents has been evaluated. The cross-linkers used were glyoxal (GO), glutaraldehyde (GA), epichlorohydrin (ECH), and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide together with N-hydroxysuccinimide (EDC-NHS), and the nanotubes were retained on graphite epoxy resin composite electrodes. The nanotube modified electrodes have been characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Using CV and EIS in the presence of potassium hexacyanoferrate(III), the electroactive area of all types of electrodes was determined and the redox process analyzed, leading to the conclusion that ECH and EDC-NHS are better for immobilization of functionalized carbon nanotubes inside the chitosan matrix. The modified electrodes were successfully applied to the determination of hydrogen peroxide by fixed potential amperometry at −0.1 V vs SCE, the highest response being exhibited when using ECH. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | American Chemical Society | en_US |
dc.rights | openAccess | eng |
dc.title | Comparative Study of Different Cross-Linking Agents for the Immobilization of Functionalized Carbon Nanotubes within a Chitosan Film Supported on a Graphite−Epoxy Composite Electrode | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1021/ac900464z | - |
item.languageiso639-1 | en | - |
item.fulltext | Com Texto completo | - |
item.grantfulltext | open | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
crisitem.author.researchunit | CEMMPRE - Centre for Mechanical Engineering, Materials and Processes | - |
crisitem.author.orcid | 0000-0002-1590-0816 | - |
crisitem.author.orcid | 0000-0002-1972-4434 | - |
Aparece nas coleções: | FCTUC Química - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Comparative Study of Different Cross-Linking.pdf | 635 kB | Adobe PDF | Ver/Abrir |
Citações SCOPUSTM
97
Visto em 4/nov/2024
Citações WEB OF SCIENCETM
1
92
Visto em 2/nov/2024
Visualizações de página
284
Visto em 5/nov/2024
Downloads
581
Visto em 5/nov/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.