Title: | Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns | Authors: | Craveiro, Hélder D. Rahnavard, Rohola Henriques, José Simões, Rui A. |
Keywords: | cold-formed steel; built-up section; concrete-filled; load-bearing capacity; local-global buckling interaction; global buckling; fastener spacing | Issue Date: | 15-Mar-2022 | Project: | FCT - 2020.03588.CEECIND FCT - research project PTDC/ECI-EGC/31858/2017—INNOCFSCONC—innovative hybrid structural solutions using cold-formed steel and lightweight concrete financed by FEDER funds through the Competitivity Factors Operational Programme-COMPETE and by national funds through FCT, PCIF/AGT/0062/2018—INTERFACESEGURA—Segurança e Resiliência ao Fogo das Zonas e Interface Urbana-Florestal UIDB/04029/2020 |
Serial title, monograph or event: | Materials | Volume: | 15 | Issue: | 6 | Abstract: | Concrete-filled composite columns are widely used in the construction industry, exploiting the benefits of combining steel and concrete, providing, for instance, high load-bearing capacities and enhanced fire resistance. These solutions are extensively used in high-rise buildings and/or when high fire resistance performance requirements are imposed. In this exploratory research, a new type of concrete-filled composite column is investigated using fire resistance tests. Promoting the use of cold-formed steel products and developing innovative solutions for low-rise buildings with lower passive fire protection requirements led to the solutions presented in this research. Hence, a set of fire-resistance tests were undertaken on concrete-filled closed built-up cold-formed steel columns, where single cold-formed steel shapes are combined and fastened to create a box-shaped cross-section. The experimental results were then compared with the corresponding bare steel solutions to assess, in detail, the observed enhancements. Additionally, the effect of restraint on thermal elongation was assessed. | URI: | http://hdl.handle.net/10316/103358 | ISSN: | 1996-1944 | DOI: | 10.3390/ma15062159 | Rights: | openAccess |
Appears in Collections: | I&D ISISE - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Structural-Fire-Performance-of-ConcreteFilled-BuiltUp-ColdFormed-Steel-ColumnsMaterials.pdf | 4.18 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
12
checked on Sep 1, 2023
WEB OF SCIENCETM
Citations
11
checked on Sep 2, 2023
Page view(s)
11
checked on Sep 18, 2023
Download(s)
22
checked on Sep 18, 2023
Google ScholarTM
Check
Altmetric
Altmetric
This item is licensed under a Creative Commons License