Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/10317
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Matysik, Frank-Michael | - |
dc.contributor.author | Matysik, Silke | - |
dc.contributor.author | Brett, Ana Maria Oliveira | - |
dc.contributor.author | Brett, Christopher M. A. | - |
dc.date.accessioned | 2009-06-24T14:39:37Z | - |
dc.date.available | 2009-06-24T14:39:37Z | - |
dc.date.issued | 1997-04-15 | - |
dc.identifier.citation | Analytical Chemistry. 69:8 (1997) 1651-1656 | en_US |
dc.identifier.issn | 0003-2700 | - |
dc.identifier.uri | https://hdl.handle.net/10316/10317 | - |
dc.description.abstract | The high mass transport caused by ultrasonic radiation in the preconcentration of trace metal species in anodic stripping voltammetry (ASV), leads to an order of magnitude enhancement in sensitivity. A Nafion-coated mercury thin-film working electrode is placed in a specially designed small-volume sonovoltammetric cell. The preparation and curing procedure for the Nafion film on a glassy carbon electrode substrate as well as ultrasound-enhanced mercury deposition through the Nafion film are optimized. The resulting electrode assembly is stable under ultrasonic irradiation. Optical microscopy observations show the formation of closely spaced mercury droplets of micrometer dimensions under the Nafion film. The performance characteristics of ultrasound-enhanced ASV at the Nafion-coated mercury thin-film electrode are studied in detail. The detection limit obtained for lead and cadmium test species is 3 × 10-11 M (30 s preconcentration in the presence of ultrasound). A relative standard deviation of 1.2% is obtained for repetitive determinations of 10 nM Cd2+ (n = 9). | en_US |
dc.language.iso | eng | en_US |
dc.publisher | American Chemical Society | en_US |
dc.rights | openAccess | eng |
dc.title | Ultrasound-Enhanced Anodic Stripping Voltammetry Using Perfluorosulfonated Ionomer-Coated Mercury Thin-Film Electrodes | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1021/ac960815j | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.fulltext | Com Texto completo | - |
item.languageiso639-1 | en | - |
crisitem.author.researchunit | CEMMPRE - Centre for Mechanical Engineering, Materials and Processes | - |
crisitem.author.orcid | 0000-0002-6244-0891 | - |
crisitem.author.orcid | 0000-0002-1972-4434 | - |
Appears in Collections: | FCTUC Química - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Ultrasound-Enhanced Anodic Stripping.pdf | 243.19 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
88
checked on Apr 1, 2024
WEB OF SCIENCETM
Citations
1
85
checked on Apr 2, 2024
Page view(s) 50
474
checked on Apr 16, 2024
Download(s)
349
checked on Apr 16, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.