Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/101854
DC FieldValueLanguage
dc.contributor.authorAwad, Mohammad I.-
dc.contributor.authorGan, Dongming-
dc.contributor.authorHussain, Irfan-
dc.contributor.authorAz-Zu'bi, Ali-
dc.contributor.authorStefanini, Cesare-
dc.contributor.authorKhalaf, Kinda-
dc.contributor.authorZweiri, Yahya-
dc.contributor.authorDias, Jorge-
dc.contributor.authorSeneviratne, Lakmal D.-
dc.date.accessioned2022-09-16T11:28:28Z-
dc.date.available2022-09-16T11:28:28Z-
dc.date.issued2018-
dc.identifier.issn2169-3536pt
dc.identifier.urihttps://hdl.handle.net/10316/101854-
dc.description.abstractIn this paper we present the design, development and experimental validation of a novel Binary-Controlled Variable Stiffness Joint (BpVSJ) towards haptic teleoperation and human interaction manipulators applications. The proposed actuator is a proof of concept of a passive revolute joint, where the working principle is based on the recruitment of series-parallel elastic elements. The novelty of the system lies in its design topology, including the capability to involve an (n) number of series-parallel elastic elements to achieve (2n) levels of stiffness, as compared to current approaches. Accordingly, the level of stiffness can be altered at any position without the need to revert to the initial equilibrium position. The BpVSJ has low energy consumption and short switching time, and is able to rotate freely at zero stiffness without limitations. Further smart features include scalability and relative compactness. This paper details the mathematical stiffness modeling of the proposed actuator mechanism, as well as the experimentally measured performance characteristics. The experimental results matched well with the physical-based modeling in terms of stiffness variation levels. Moreover, Psychophysical experiments were also conducted using (20) healthy subjects in order to evaluate the capability of the BpVSJ to display three different levels of stiffness that are cognitively realized by the users. The participants performed two tasks: a relative cognitive task and an absolute cognitive task. The results show that the BpVSJ is capable of rendering stiffness with high average relative accuracy (Relative Cognitive Task relative accuracy is 97.3%, and Absolute Cognitive Task relative accuracy is 83%).pt
dc.language.isoengpt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt
dc.subjectVariable Stiffness Mechanismpt
dc.subjectPassive Haptic Interfacept
dc.subjectPsychophysical Taskspt
dc.titleDesign of A Novel Passive Binary-Controlled Variable Stiffness Joint (BpVSJ) Towards Passive Haptic Interface Applicationpt
dc.typearticle-
degois.publication.firstPage63045pt
degois.publication.lastPage63057pt
degois.publication.titleIEEE Accesspt
dc.peerreviewedyespt
dc.identifier.doi10.1109/ACCESS.2018.2876802pt
degois.publication.volume6pt
dc.date.embargo2018-01-01*
uc.date.periodoEmbargo0pt
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.openairetypearticle-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.researchunitISR - Institute of Systems and Robotics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-2725-8867-
Appears in Collections:I&D ISR - Artigos em Revistas Internacionais
Show simple item record

SCOPUSTM   
Citations

16
checked on Nov 9, 2022

WEB OF SCIENCETM
Citations

13
checked on May 2, 2023

Page view(s)

101
checked on Apr 24, 2024

Download(s)

67
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons