dc.description.abstractAim: The purpose of the present study is to assess the color stability of two calcium silicate-based cements (CSCs) used in regenerative endodontic procedures (REPs). Methods: A total of 40 acrylic single-rooted transparent teeth, with immature apex, were used. Root canals were filled up to 3 mm below the level of the cementoenamel junction, with either saline solution (Mineral Trioxide Aggregate (MTA)/saline and Biodentine/saline) or blood (MTA/blood and Biodentine/blood). Subsequently, ProRoot MTA® or BiodentineTM was placed in the root canal to create a cervical barrier. Color measurement was carried out at four different evaluation periods (3 h, 72 h, 7 days, and 6 months). Shade analysis within the L* a* b* color space was performed and color variation (∆E) calculated. The significance level for statistical analysis was set at p < 0.05. Results: The four groups showed a significant decrease in L* values over time. The ∆E value increased over time for all groups but was not statistically significant for the Biodentine/blood group. Two-way ANOVA showed no interaction between the CSC and treatment (contact with saline solution or blood). CSC used was the factor responsible for ∆E over time, inducing statistically significant color variations from T3H to T7D (p = 0.04) and T3H to T6M (p < 0.01). After 6 months, MTA/saline had 5.08 (p = 0.001) higher ∆E than Biodentine/Saline and the MTA/blood had 3.65 (p = 0.009) higher than Biodentine/blood. Conclusions: After 6 months, regardless of blood exposure, Biodentine exhibits superior color stability compared to MTA. Biodentine might be a suitable alternative to MTA as a cervical barrier material in REPs.pt
dc.language.isoengpt
dc.rightsopenAccesspt
dc.subjectBiodentinept
dc.subjectcalcium silicate-based cementspt
dc.subjectmineral trioxide aggregatept
dc.subjectregenerative endodontic procedurespt
dc.subjecttooth discolorationpt
dc.titleSix-Month Color Stability Assessment of Two Calcium Silicate-Based Cements Used in Regenerative Endodontic Procedurespt
dc.typearticleen_US
degois.publication.firstPage14pt
degois.publication.issue1pt
degois.publication.titleJournal of Functional Biomaterialspt
dc.date.updated2022-03-01T23:04:22Z-
dc.peerreviewedyespt
dc.identifier.doi10.3390/jfb10010014pt
degois.publication.volume10pt
dc.description.version4110-6966-DEF9 | Paulo Jorge Rocha da Palma-
dc.description.versioninfo:eu-repo/semantics/publishedVersion-
dc.identifier.slugcv-prod-2790744-
dc.date.embargo2019-02-28*
uc.date.periodoEmbargo0pt
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.deptFaculty of Medicine-
crisitem.author.parentdeptUniversity of Coimbra-
crisitem.author.orcid0000-0003-4730-8072-
crisitem.author.orcid0000-0001-7099-8871-
crisitem.author.orcid0000-0002-2865-9689-
crisitem.author.orcid0000-0003-1965-1092-
Appears in Collections:FMUC Med. Dentária - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
jfb-Six-Month_Color_Stability.pdf2.37 MBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

29
checked on Apr 1, 2024

WEB OF SCIENCETM
Citations

23
checked on Apr 2, 2024

Page view(s)

121
checked on Apr 9, 2024

Download(s)

40
checked on Apr 9, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.