dc.description.abstractGiven the Portuguese national programme for rehabilitation of school buildings and the new regulations for thermal comfort and air quality in Portugal, whose demands contribute to increase energy costs, it became relevant to study a case before any refurbishment intervention, in order to assess the potential of different methods of actions and to improve results. It was also intended with this study to evaluate the indoor thermal quality and the indoor air quality experienced by the school occupants. From a practical case, a school in Coimbra, the procedure passed through the measurement of some environmental physical parameters [dry bulb temperature and relative humidity and the concentrations of chemical indicators, such as carbon monoxide and carbon dioxide]. Contributing to the indoor environment characterization, it was developed a survey directed to the occupants, in parallel with the measurements taken inside a classroom during a period in the heating season and another period in the ‘pre-cooling’ season. An estimation of the predicted percentage of dissatisfied and predicted mean vote comfort indices was done based on the school measured data. The results were compared with those obtained from the questionnaire. In the end, an analysis was also done based on CO2 concentration values.pt
dc.language.isoengpt
dc.publisherSAGEpt
dc.relationSFRH/BD/77105/2011pt
dc.rightsembargoedAccesspt
dc.subjectIndoor air qualitypt
dc.subjectThermal comfortpt
dc.subjectIndoor carbon dioxidept
dc.subjectSchoolpt
dc.subjectPMV/PPD indicespt
dc.titleIndoor air quality audit and evaluation on thermal comfort in a school in Portugalpt
dc.typearticle-
degois.publication.firstPage256pt
degois.publication.lastPage268pt
dc.relation.publisherversionhttps://journals.sagepub.com/doi/abs/10.1177/1420326X13508966pt
dc.peerreviewedyespt
dc.identifier.doi10.1177/1420326X13508966pt
degois.publication.volume24pt
dc.date.embargo2015-01-01*
uc.date.periodoEmbargo0pt
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.author.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.author.researchunitLAETA - Associated Laboratory for Energy, Transports and Aeronautics-
crisitem.author.orcid0000-0003-1312-8137-
crisitem.author.orcid0000-0003-0739-9811-
Appears in Collections:FCTUC Eng.Mecânica - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
Dias Pereira_IBE 2013_Uncorrected proof.pdfUncorrected proof_Accepted manuscript2.29 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.