Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/88879
DC FieldValueLanguage
dc.contributor.authorVentura, Tiago-
dc.contributor.authorLopes, Maria do Carmo Carrilho Calado Antunes-
dc.contributor.authorRocha, Humberto-
dc.contributor.authorFerreira, Brigida da Costa-
dc.contributor.authorDias, Joana-
dc.date.accessioned2020-02-18T09:42:11Z-
dc.date.available2020-02-18T09:42:11Z-
dc.date.issued2020-
dc.identifier.isbn978-3-030-31634-1pt
dc.identifier.urihttps://hdl.handle.net/10316/88879-
dc.description.abstractRadiation therapy (RT) main purpose is to eliminate, in a controlled way, all tumor cells sparing as much as possible the normal tissues. Intensity-Modulated Radiation Therapy (IMRT) is becoming the standard treatment technique in RT. Beam angle optimization (BAO) has potential to confer more quality to IMRT inverse planning process compared to manual trial and error approaches. In this study, the BAO advantages in head-and-neck patients are highlighted, using a patient specific analysis. Fluence optimization was done with Erasmus-iCycle multicriterial engine and BAO optimization was performed using two different algorithms: a combinatorial iterative algorithm and an algorithm based on a pattern search method. Plan assessment and comparison was performed with the graphical tool SPIDERplan. Among a set of forty studied nasopharynx cancer cases, three patients have been select for the specific analysis presented in this work. BAO presented plan quality improvements when beam angular optimized plans were compared with the equidistant beam angle solution and when plans based on non-coplanar beams geometries were compared with coplanar arrangements. Improvement in plan quality with a reduced number of beams was also achieved, in one case. For all cases, BAO generated plans with higher target coverage and better sparing of the normal tissues.pt
dc.language.isoengpt
dc.publisherSpringerpt
dc.rightsopenAccesspt
dc.subjectRadiation therapypt
dc.subjectBeam angle optimizationpt
dc.titleAdvantage of Beam Angle Optimization in Head-and-Neck IMRT: Patient Specific Analysispt
dc.typebookPart-
degois.publication.firstPage1256pt
degois.publication.lastPage1263pt
degois.publication.titleIFMBEpt
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007/978-3-030-31635-8_153#citeaspt
dc.peerreviewedyespt
dc.identifier.doi10.1007/978-3-030-31635-8_153pt
degois.publication.volume76pt
dc.date.embargo2020-01-01*
uc.date.periodoEmbargo0pt
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypebookPart-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitINESC Coimbra – Institute for Systems Engineering and Computers at Coimbra-
crisitem.author.researchunitINESC Coimbra – Institute for Systems Engineering and Computers at Coimbra-
crisitem.author.researchunitINESC Coimbra – Institute for Systems Engineering and Computers at Coimbra-
crisitem.author.researchunitCeBER – Centre for Business and Economics Research-
crisitem.author.orcid0000-0003-1562-0387-
crisitem.author.orcid0000-0001-7339-7342-
crisitem.author.orcid0000-0002-5981-4469-
Appears in Collections:I&D CeBER - Livros e Capítulos de Livros
Files in This Item:
File Description SizeFormat
MEDICON2019_paper_58.pdfAdvantage of Beam Angle Optimization in Head-and-Neck IMRT: Patient Specific Analysis716.87 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

2
checked on Apr 1, 2024

WEB OF SCIENCETM
Citations 20

2
checked on Apr 2, 2024

Page view(s)

315
checked on Apr 16, 2024

Download(s)

373
checked on Apr 16, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.