Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/8358
DC FieldValueLanguage
dc.contributor.authorSarmento, Bruno-
dc.contributor.authorRibeiro, António-
dc.contributor.authorVeiga, Francisco-
dc.contributor.authorFerreira, Domingos-
dc.date.accessioned2009-02-09T14:51:17Z-
dc.date.available2009-02-09T14:51:17Z-
dc.date.issued2006en_US
dc.identifier.citationBiomedical Chromatography. 20:9 (2006) 898-903en_US
dc.identifier.urihttps://hdl.handle.net/10316/8358-
dc.description.abstractA reversed-phase high-performance liquid chromatographic (HPLC) method has been developed and validated for the determination of insulin in nanoparticulate dosage forms. Its application for the development and characterization of insulin-loaded nanoparticulates composed of polyelectrolytes has also been carried out. A reversed-phase (RP) C18 column and gradient elution with a mobile phase composed of acetonitrile (ACN) and 0.1% aqueous trifluoroacetic acid (TFA) solution at a flow rate of 1 mL/min was used. Protein identification was made by UV detection at 214 nm. The gradient changed from 30:70 (ACN:TFA, v/v) to 40:60 (v/v) in 5 min followed by isocratic elution at 40:60 (v/v) for a further five minutes. The method was linear in the range of 1-100 µg/mL (R2 = 0.9996), specific with a good inter-day and intra-day precision based on relative standard deviation values (less than 3.80%). The recovery was between 98.86 and 100.88% and the detection and quantitation limits were 0.24 and 0.72 µg/mL, respectively. The method was further tested for the determination of the association efficiency of insulin to nanoparticulate carriers composed of alginate and chitosan, as well as its loading capacity for this protein. Encapsulant release under simulated gastrointestinal fluids was evaluated. The method can be used for development and characterization of insulin-loaded nanoparticles made from cross-linked chitosan-alginate. Copyright © 2006 John Wiley & Sons, Ltd.en_US
dc.language.isoengeng
dc.rightsopenAccesseng
dc.titleDevelopment and validation of a rapid reversed-phase HPLC method for the determination of insulin from nanoparticulate systemsen_US
dc.typearticleen_US
dc.identifier.doi10.1002/bmc.616en_US
uc.controloAutoridadeSim-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.orcid0000-0002-1041-0068-
Appears in Collections:FFUC- Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
obra.pdf134.36 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

93
checked on Apr 15, 2024

WEB OF SCIENCETM
Citations 1

91
checked on Apr 2, 2024

Page view(s) 5

1,260
checked on Apr 16, 2024

Download(s) 50

846
checked on Apr 16, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.