Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/7690
DC FieldValueLanguage
dc.contributor.authorKottmann, F.-
dc.contributor.authorAmir, W.-
dc.contributor.authorBiraben, F.-
dc.contributor.authorConde, C.-
dc.contributor.authorDhawan, S.-
dc.contributor.authorHänsch, T.-
dc.contributor.authorHartmann, F.-
dc.contributor.authorHughes, V.-
dc.contributor.authorHuot, O.-
dc.contributor.authorIndelicato, P.-
dc.contributor.authorJulien, L.-
dc.contributor.authorKnowles, P.-
dc.contributor.authorKazamias, S.-
dc.contributor.authorLiu, Y.-W.-
dc.contributor.authorMulhauser, F.-
dc.contributor.authorNez, F.-
dc.contributor.authorPohl, R.-
dc.contributor.authorRabinowitz, P.-
dc.contributor.authorSantos, J. M. F. dos-
dc.contributor.authorSchaller, L.-
dc.contributor.authorSchneuwly, H.-
dc.contributor.authorSchott, W.-
dc.contributor.authorTaqqu, D.-
dc.contributor.authorVeloso, J.-
dc.date.accessioned2009-02-17T10:29:42Z-
dc.date.available2009-02-17T10:29:42Z-
dc.date.issued2001en_US
dc.identifier.citationHyperfine Interactions. 138:1 (2001) 55-60en_US
dc.identifier.urihttps://hdl.handle.net/10316/7690-
dc.description.abstractAbstract A measurement of the 2S Lamb shift in muonic hydrogen (µ-p) is being prepared at the Paul Scherrer Institute (PSI). The goal of the experiment is to measure the energy difference ?E(25 P 3/2-23 S 1/2) by laser spectroscopy (?˜6µm) to a precision of 30 ppm and to deduce the root mean square (rms) proton charge radius with 10-3 relative accuracy, 20 times more precise than presently known. An important prerequisite to this experiment is the availability of long-lived µp2S -atoms. A 2S-lifetime of ~1 µs – sufficiently long to perform the laser experiment – at H2 gas pressures of 1–2 hPa was deduced from recent measurements of the collisional 2S-quenching rate. A new low-energy negative muon beam yields an order of magnitude more muon stops in a small low-density gas volume than a conventional cloud muon beam. A stack of ultra-thin carbon foils is the key element of a fast detector for keV-muons. The development of a 2 keV X-ray detector and a 3-stage laser system providing 0.5 mJ laser pulses at 6 µm is on the way.en_US
dc.language.isoengeng
dc.rightsopenAccesseng
dc.titleThe Muonic Hydrogen Lamb Shift Experiment at PSIen_US
dc.typearticleen_US
dc.identifier.doi10.1023/A:1020886314237en_US
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0003-4668-8958-
crisitem.author.orcid0000-0002-8841-6523-
crisitem.author.orcid0000-0002-7107-7203-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
obra.pdf77.43 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

42
checked on Apr 1, 2024

WEB OF SCIENCETM
Citations 5

37
checked on Apr 2, 2024

Page view(s)

243
checked on Apr 16, 2024

Download(s)

273
checked on Apr 16, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.