Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/5283
Título: Flow-injection determination of catechol with a new tyrosinase/DNA biosensor
Autor: Dantoni, Patrícia 
Serrano, Sílvia H. P. 
Brett, Ana Maria Oliveira 
Gutz, Ivano G. R. 
Palavras-chave: DNA biosensor; Tyrosinase; Catechol determinations; Amperometric flow analysis
Data: 1998
Citação: Analytica Chimica Acta. 366:1-3 (1998) 137-145
Resumo: Biosensors find application in flow analysis due to their high selectivity and sensitivity. Decrease in the response during extended use, originated by degradation, inhibition or structural changes of the enzyme or leaching of active components by the flow, is the prevailing problem. As an alternative to additives and preparation techniques cited in the literature, it is proposed to use DNA as a matrix for improving preservation of the activity of a diphenol-sensor-based tyrosinase, Tyr, (EC 1.14.18.1). The Tyr-DNA mixture was incorporated into carbon paste, CP-DNA-Tyr, or applied on glassy carbon, GC-DNA-Tyr. The CP-DNA-Tyr, covered by a membrane -of Cuprophan, presented superior performance in amperometric operation under flow conditions (electroreduction of the products of the enzymatic oxidation of diphenols in the presence of O2). In comparison with paste electrodes without DNA, CP-Tyr, a current increase of one order of magnitude was observed for catechol FIA peaks, with good repeatability during several hours of operation. The response decayed ca. 50% after every 3 to 4 days of use (with dry storage at 4°C overnight). Original performance was recovered by simply substituting the used paste for a new portion of stock paste, stable for 2 months under refrigeration. Evaluation of 18 different substrates and potential interferents indicated that, at the adopted potential of -0,15 V vs. Ag/AgCl, only p-cresol gives a response comparable to catechol. Flow-injection determination of catechol samples was conducted at a frequency of 30 injections/h, with linear response from the detection limit of 1×10-6 up to 5×10-5 mol l-1.
URI: https://hdl.handle.net/10316/5283
DOI: 10.1016/s0003-2670(98)00102-0
Direitos: openAccess
Aparece nas coleções:FCTUC Química - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
file639a25f4d4364cac85bf25f7f03bad43.pdf277.21 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações WEB OF SCIENCETM

50
Visto em 2/abr/2024

Visualizações de página

279
Visto em 23/abr/2024

Downloads 50

453
Visto em 23/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.