Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/4554
DC FieldValueLanguage
dc.contributor.authorSilva, Rui M. C.-
dc.contributor.authorSantos, J. M. F. dos-
dc.contributor.authorConde, C. A. N.-
dc.date.accessioned2008-09-01T11:09:05Z-
dc.date.available2008-09-01T11:09:05Z-
dc.date.issued1999en_US
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 422:1-3 (1999) 305-308en_US
dc.identifier.urihttps://hdl.handle.net/10316/4554-
dc.description.abstractGas Proportional Scintillation Counters using curved grids for solid angle and reflection compensation have been described in the recent literature. They allow large radiation windows with diameters of 25 mm keeping at the same time the good energy resolutions characteristic of those X-ray detectors. However, the grids used have a spherical curvature, which does not correspond to the optimal curvature. In the present work we have calculated by computer simulation an improved shape for the curved grid. This shape can be well fitted to an ellipsoid of revolution, with a large eccentricity. A detector was designed with such an ellipsoidal grid and a radiation window 40 mm in diameter, filled with pure xenon at 927 Torr coupled to an EMI D676QB VUV photomultiplier tube having a 2'' diameter window. For the experiments envisaged, detection of solar X-rays in the 20-80 keV energy range, a 7 cm thick drift region was used, leading to efficiencies from 80% to 20%, respectively. Such a thick drift region reduces the performance mainly for soft X-rays. For 22 keV X-rays the energy resolution obtained, for a broad X-ray beam entering the full 40 mm diameter detector window, is 6.0%. Results are presented showing the variation of the energy resolution with the window diameter and a performance, for ellipsoidal grids superior to that for spherical grids. A discussion of the results obtained is presented.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-3VR1CVW-26/1/928927b1cf3cb22ebfa404018a2bdbaeen_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectScintillation countersen_US
dc.subjectX-ray detectorsen_US
dc.subjectEllipsoiden_US
dc.subjectCurved grid techniqueen_US
dc.titleAn ellipsoidal grid gas proportional scintillation counteren_US
dc.typearticleen_US
dc.identifier.doi10.1016/S0168-9002(98)00963-2-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.deptFaculty of Sciences and Technology-
crisitem.author.parentdeptUniversity of Coimbra-
crisitem.author.researchunitLIP – Laboratory of Instrumentation and Experimental Particle Physics-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-9961-965X-
crisitem.author.orcid0000-0002-8841-6523-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
file29f2905b59014d4da7d51b589dd4dd59.pdf163.23 kBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.