Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/4499
Title: Development of large area and of position-sensitive timing RPCs
Authors: Blanco, A. 
Marques, R. Ferreira 
Finck, Ch. 
Fonte, P. 
Gobbi, A. 
Mendiratta, S. K. 
Monteiro, J. 
Policarpo, A. 
Rozas, M. 
Keywords: Gaseous detectors; Time resolution
Issue Date: 2002
Citation: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 478:1-2 (2002) 170-175
Abstract: Resistive Plate Chambers (RPC) made with glass and metal electrodes forming accurately spaced gas gaps of a few hundred micrometers have reached timing accuracies below 50 ps [sigma] with efficiencies above 99% for MIPs. This type of detector, operating at atmospheric pressure with non-flammable gases, seems well suited for large TOF systems, providing performances comparable to the scintillator-based TOF technology with significantly lower price per channel and being compatible with magnetic fields.
URI: https://hdl.handle.net/10316/4499
DOI: 10.1016/S0168-9002(01)01749-1
Rights: openAccess
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais

Files in This Item:
File Description SizeFormat
file3ad728d6f6dd4071887eb091129e390d.pdf242.01 kBAdobe PDFView/Open
Show full item record

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.