dc.date.issued2003en_US
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 515:3 (2003) 618-623en_US
dc.identifier.urihttps://hdl.handle.net/10316/4461-
dc.description.abstractThe response of a cadmium zinc telluride (CZT) detector to X-rays with energies around the Zn, Cd and Te K-absorption edges was investigated. The energy non-linearity in the detector response at the K-edges is less than 0.1%, within the experimental errors. No abrupt variation in both the w-value and the detector energy resolution was observed at the K-edges, a behaviour consistent with the absence of intrinsic non-linearity effects in CZT. Within the accuracy of our measurements, we conclude that there are no non-linearity effects in CZT semiconductors at the Zn, Cd and Te K-edges.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-49FPGXT-M/1/4034301504a01eb84c982e6c4626891aen_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectEnergy linearityen_US
dc.subjectK-edgesen_US
dc.subjectX-ray detectorsen_US
dc.titleEnergy linearity response of CZT detectors to X-rays in the region of the Zn, Cd and Te K-absorption edges: experimental resultsen_US
dc.typearticleen_US
dc.identifier.doi10.1016/j.nima.2003.06.005-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0001-8235-3229-
crisitem.author.orcid0000-0002-8832-8208-
crisitem.author.orcid0000-0002-7107-7203-
crisitem.author.orcid0000-0002-8841-6523-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
filec6897aec8ee243f5a529d739e287b67d.pdf128.32 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

4
checked on Apr 22, 2024

WEB OF SCIENCETM
Citations

2
checked on Apr 2, 2024

Page view(s)

266
checked on Apr 23, 2024

Download(s)

264
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.