Title: | MHSP operation in pure xenon | Authors: | Luz, H. Natal da Veloso, J. F. C. A. Amaro, F. D. Ferreira, L. F. Requicha Santos, J. M. F. dos Breskin, A. Chechik, R. |
Keywords: | Gas electron multiplier | Issue Date: | 2005 | Citation: | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 552:3 (2005) 259-262 | Abstract: | We present latest results of a micro-hole and strip plate (MHSP) electron multiplier operating in pure xenon at atmospheric pressure. We report on avalanche gain of ~2×104, stable within ~3% after an accumulated charge of 4 [mu]C/mm2, when irradiated with 0.5 kHz/mm2 5.9 keV photons. No photon-induced secondary effects or discharges have been observed at this gain. An energy resolution of 14% was obtained with 5.9 keV X-rays. | URI: | http://hdl.handle.net/10316/4417 | DOI: | 10.1016/j.nima.2005.07.004 | Rights: | openAccess |