Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/4375
Campo DCValorIdioma
dc.contributor.authorCoelho, L. C. C.-
dc.contributor.authorLopes, J. A. M.-
dc.contributor.authorCovita, D. S.-
dc.contributor.authorConceição, A. S.-
dc.contributor.authorSantos, J. M. F. dos-
dc.date.accessioned2008-09-01T11:06:03Z-
dc.date.available2008-09-01T11:06:03Z-
dc.date.issued2007en_US
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 575:3 (2007) 444-448en_US
dc.identifier.urihttps://hdl.handle.net/10316/4375-
dc.description.abstractThe performance of a xenon high-pressure gas proportional scintillation counter (GPSC) instrumented with a large area avalanche photodiode (LAAPD) as the VUV-photosensor has been investigated for filling pressures from 1 up to 10 bar, for 22- and 60-keV photons. The LAAPD photosensor is placed directly within the xenon envelope, as a substitute for the photomultiplier tube, avoiding the constraints of the use of a quartz scintillation window for GPSC-photosensor coupling, which absorbs a significant amount of scintillation and is a drawback for applications where large detection areas and high filling pressures are needed. The lowest energy resolutions are achieved for pressures around 5 bar (4.5% and 3.0% full width at half-maximum (FWHM), for 22- and 60-keV photons, respectively). Increasing the pressure to the 8 bar range, competitive energy resolutions of 5.0% and 3.6% are still achieved for 22- and 60-keV photons, respectively. This detector could be a compelling alternative in applications where compactness, large detection area, insensitivity to strong magnetic fields, room temperature operation, large signal-to-noise ratio and good energy resolution are important requirements.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-4N7XP3B-2/1/b0382cbbf64836cc7a6321fb3255cf3den_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectX-ray detectionen_US
dc.subjectGas proportional counteren_US
dc.titleXenon GPSC high-pressure operation with large-area avalanche photodiode readouten_US
dc.typearticleen_US
dc.identifier.doi10.1016/j.nima.2007.02.111-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.openairetypearticle-
item.languageiso639-1en-
item.fulltextCom Texto completo-
item.cerifentitytypePublications-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-8841-6523-
Aparece nas coleções:FCTUC Física - Artigos em Revistas Internacionais
Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
file9bd3beff04a14d628881201c1da02af9.pdf290.54 kBAdobe PDFVer/Abrir
Mostrar registo em formato simples

Citações SCOPUSTM   

16
Visto em 19/ago/2024

Citações WEB OF SCIENCETM

13
Visto em 2/ago/2024

Visualizações de página

271
Visto em 27/ago/2024

Downloads

300
Visto em 27/ago/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.