dc.identifier.citation | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 580:1 (2007) 362-365 | en_US |
dc.identifier.uri | https://hdl.handle.net/10316/4361 | - |
dc.description.abstract | We report the performance of the Micro-Hole-and-Strip-Plate (MHSP) operated in xenon, under high-flux irradiation of a 30-kV X-ray Cu-tube. Stable operation in pulse-counting mode for gas gains above 104 was measured up to counting rates of 5×105 Hz/mm2. A gain variation of less than 5% was observed for gains of 104, while the energy resolution for 8-keV X-rays degrades from ~16% to ~18%. No visible degradation was observed on the MHSP irradiated area. | en_US |
dc.description.uri | http://www.sciencedirect.com/science/article/B6TJM-4NTB92C-5/1/ae310ff6f302c176c09b7d1efd012ab1 | en_US |
dc.format.mimetype | aplication/PDF | en |
dc.language.iso | eng | eng |
dc.rights | openAccess | eng |
dc.subject | Count rate | en_US |
dc.title | High-rate operation of the Micro-Hole and Strip Plate gas detector | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1016/j.nima.2007.05.179 | - |
item.openairetype | article | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.fulltext | Com Texto completo | - |
crisitem.author.researchunit | LIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics | - |
crisitem.author.parentresearchunit | University of Coimbra | - |
crisitem.author.orcid | 0000-0002-7107-7203 | - |
crisitem.author.orcid | 0000-0002-8841-6523 | - |
Appears in Collections: | FCTUC Física - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
file1cf8cc57e48a40cd87535b6e690522ce.pdf | 1.04 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
8
checked on Mar 25, 2024
WEB OF SCIENCETM
Citations
7
checked on Mar 2, 2024
Page view(s) 50
432
checked on Mar 26, 2024
Download(s) 50
537
checked on Mar 26, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.