Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/33167
Título: | Training and Interobserver Reliability in Qualitative Scoring of Skeletal Samples | Autor: | Wilczak, C. Mariotti, V. Pany-Kucera, D. Villotte, S. Henderson, Charlotte |
Palavras-chave: | Anthropology; Archaeology | Data: | Nov-2016 | Editora: | Journal of Archaeological Science: Reports | Projeto: | Wenner-Gren Foundation (grant number Gr. CONF-632) Fundação para a Ciência e a Tecnologia SFRH/BPD82559/2011 Fundação para a Ciência e a Tecnologia FCT/Pest-OE/SADG/UI0283/20113 |
Volume: | 11 | Local de edição ou do evento: | Journal of Archaeological Science: Reports | Resumo: | This article reports on inter- and intra-observer reliability testing of the Coimbra method for fibrocartilaginous entheseal changes and discusses the results in the context of reliability for other qualitative methods that score skeletal variation. Four tests of interobserver and one test of intraobserver reliability were conducted. Three of the interobserver tests were conducted in person (Geneva, Coimbra A, Coimbra B) and one was conducted on-line. Before each test, the observers trained together and refinements were made to the method. Inter- and intra-observer reliability was assessed using percentage agreement, kappa scores, and Krippendorff’s alpha. On-line testing had the lowest reliability (60% agreement, κ = 0.292, α = 0.369). Final reliability results in the Coimbra B test increased from the initial Geneva test (68.6 to 80.0% agreement, κ = 0.522 to 0.589, α = 0.604 to 0.666). Factors such as training, observation conditions, visual acuity, and differences in interpretation of scoring criteria impact reliability. Suggestions are made to address the general problem of reliability in qualitative methods. | URI: | https://hdl.handle.net/10316/33167 | DOI: | 10.1016/j.jasrep.2016.11.033 | Direitos: | closedAccess |
Aparece nas coleções: | I&D CIAS - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | Entrar |
---|---|---|---|---|
Wilczak et al 2017 error paper.pdf | 996.44 kB | Adobe PDF | Pedir uma cópia |
Citações SCOPUSTM
33
Visto em 15/abr/2024
Citações WEB OF SCIENCETM
5
29
Visto em 2/abr/2024
Visualizações de página
238
Visto em 16/abr/2024
Downloads 10
1.346
Visto em 16/abr/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.