Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/27276
DC FieldValueLanguage
dc.contributor.authorPerdigoto, Luis-
dc.contributor.authorAraujo, Helder-
dc.date.accessioned2014-10-15T09:06:16Z-
dc.date.available2014-10-15T09:06:16Z-
dc.date.issued2013-08-
dc.identifier.citationPERDIGOTO, Luis; ARAUJO, Helder - Calibration of mirror position and extrinsic parameters in axial non-central catadioptric systems. "Computer Vision and Image Understanding". ISSN 1077-3142. Vol. 117 Nº. 8 (2013) p. 909-921por
dc.identifier.issn1077-3142-
dc.identifier.urihttps://hdl.handle.net/10316/27276-
dc.description.abstractWe propose a novel calibration method for catadioptric systems made up of an axial symmetrical mirror and a pinhole camera with its optical center located at the mirror axis. The calibration estimates the relative camera/mirror position and the extrinsic rotation and translation w.r.t. the world frame. The procedure requires a single image of a (possibly planar) calibration object. We show how most of the calibration parameters can be estimated using linear methods (Direct-Linear-Transformation algorithm) and cross-ratio. Two remaining parameters are obtained by using non-linear optimization. We present experimental results on simulated and real images.por
dc.language.isoengpor
dc.publisherElsevierpor
dc.rightsopenAccesspor
dc.subjectNon-central catadioptric vision systemspor
dc.subjectCalibrationpor
dc.subjectAxial symmetric mirrorspor
dc.titleCalibration of mirror position and extrinsic parameters in axial non-central catadioptric systemspor
dc.typearticlepor
degois.publication.firstPage909por
degois.publication.lastPage921por
degois.publication.issue8por
degois.publication.titleComputer Vision and Image Understandingpor
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S1077314213000635por
dc.peerreviewedYespor
dc.identifier.doi10.1016/j.cviu.2013.04.001-
degois.publication.volume117por
uc.controloAutoridadeSim-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitISR - Institute of Systems and Robotics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-9544-424X-
Appears in Collections:I&D ISR - Artigos em Revistas Internacionais
FCTUC Eng.Electrotécnica - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
Calibration of mirror position and extrinsic parameters.pdf896.35 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

20
checked on Apr 15, 2024

WEB OF SCIENCETM
Citations 5

15
checked on May 2, 2023

Page view(s) 50

598
checked on Apr 16, 2024

Download(s) 50

640
checked on Apr 16, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.